Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 18464400 Found #76 errors of type = ERROR ch -308 v5 total power integrator overflow Found #71 errors of type = ERROR ch -308 v4 total power integrator overflow Found #62 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #35 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #26 errors of type = ERROR ch -371 IF3 alarm is on Found #19 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #15 errors of type = ERROR ch -308 vc total power integrator overflow Found #14 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #11 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #11 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #8 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #8 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #7 errors of type = ERROR ch -309 v3 alarm is on Found #6 errors of type = ERROR ch -309 vb alarm is on Found #6 errors of type = ERROR ch -309 v6 alarm is on Found #6 errors of type = ERROR ch -309 vc alarm is on Found #6 errors of type = ERROR ch -309 ve alarm is on Found #5 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR m5 -900 No scans Found #1 errors of type = ERROR ch -308 vd total power integrator overflow Found #1 errors of type = ERROR ch -308 va total power integrator overflow Found #1 errors of type = ERROR ch -348 Receiver LO is unlocked. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these RX parameters: 00(FRONT) 01(REAR) 02(LO) RX1 min= 18.98 max= 33.02 RX2 min= 24.84 max= 37.66 RX3 min= 24.84 max= 38.15 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100