Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 18460800 Found #806 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #360 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #308 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #225 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #184 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #96 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #21 errors of type = ERROR st -42 Found #18 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #16 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #11 errors of type = ERROR ch -308 v9 total power integrator overflow Found #10 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #7 errors of type = ERROR st -105 [ANCOM] - Too many errors from LU . Found #6 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #4 errors of type = ERROR ch -308 va total power integrator overflow Found #3 errors of type = ERROR ch -308 vc total power integrator overflow Found #3 errors of type = ERROR pt -102 [PTRAK] - LU has timed out. Continue tracking. Found #2 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #2 errors of type = ERROR m5 -904 MARK5 return code 4: error encountered (during attempt to execute) Found #2 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #2 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #1 errors of type = ERROR pt -103 [PTRAK] - No response from LU . PTRAK aborted. Found #1 errors of type = ERROR m5 -900 Data transfer in progress Found #1 errors of type = ERROR m5 -900 Can't get device info Found #1 errors of type = ERROR m5 -900 Previous recording still active Found #1 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #1 errors of type = ERROR m5 -900 Can't get SS version Found #1 errors of type = ERROR 5k -601 SCAN_CHECK failed Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100