Starting generation of Calibration File FS version = 0009.0006.0009 time_zero = 15397200 Found #13 errors of type = ERROR ch -308 v5 total power integrator overflow Found #12 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #8 errors of type = ERROR ch -308 v1 total power integrator overflow Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #1 errors of type = ERROR ch -309 v4 alarm is on Found #1 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found these BBCs: vc06 vc11 NBBC: 2 Found these RX parameters: 00(front) 01(rear) 02(lo) RX1 min= 19.23 max= 21.30 RX2 min= 31.56 max= 33.63 RX3 min= 44.13 max= 44.99 Plotting 2 Tsys channels: 06 11 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 2 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100