Starting generation of Calibration File FS version = 0009.0007.0005 time_zero = 14832000 Found #2312 errors of type = ERROR ma -4 Device de timed-out on response. Found #991 errors of type = ERROR ma -4 Device rx timed-out on response. Found #529 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #72 errors of type = ERROR ma -8(fm) Found #31 errors of type = ERROR ch -4 Device rx timed-out on response from MATCN Found #18 errors of type = ERROR sc -5 setcl: formatter time garbled Found #13 errors of type = ERROR sc -10 setcl: failed too many times couldn't check formatter time Found #13 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #12 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #10 errors of type = ERROR sc -15 setcl: Cannot determine NTP sync state Found #8 errors of type = ERROR sc -2 setcl: formatter time out-of-range Found #6 errors of type = ERROR sc -12 setcl: FS to computer time difference 0.5 seconds or greater Found #6 errors of type = ERROR 4f -504 Formatter and equip.ctl firmware versions disagree formatter reports 0W Found #5 errors of type = ERROR ma -4 Device fm timed-out on response. Found #3 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #3 errors of type = ERROR qa -202 Check label doesn't match. Check it and try again. Found #3 errors of type = ERROR m5 -23 mk5cn: socket open error from getsockopt() Found #3 errors of type = ERROR un 115 Operation now in progress Found #2 errors of type = ERROR sc -13 setcl: formatter to FS time difference 0.5 seconds or greater Found #1 errors of type = ERROR an -102 Pointing computer command angles are incorrect. Found #1 errors of type = ERROR ma -807 MK4 FM don't recognize command Found #1 errors of type = ERROR m5 -907 MARK5 return code 7: no such keyword Found #1 errors of type = ERROR mc -2 Interface b3 responded but did not ACKnowledge. Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR ma -701 MK4 DE unknown command Found #1 errors of type = ERROR m5 -900 Unknown keyword Found #1 errors of type = ERROR qn -201 Error in request. Unknown module or does not match your equipment. Found these BBCs: bbc02 bbc06 bbc11 NBBC: 3 Found these RX parameters: front 02(lo) dcal RX1 min= 100000 max= -1 RX2 min= 282.1 max= 282.1 RX3 min= 100000 max= -1 Can't plot RX2 Plotting 3 Tsys channels: 02 06 11 Tsysa values are: etc Tsysb values are: etc Tsysc values are: etc Tsysd values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100