Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 27018000 Found #694 errors of type = ERROR st -14 Antenna stuck. Found #35 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #35 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #27 errors of type = ERROR ib -4 GPIB Device time-out on response cb Found #22 errors of type = ERROR ch -308 vb total power integrator overflow Found #16 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #14 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 40K. Found #14 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #14 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #5 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #3 errors of type = ERROR ib -4 GPIB Device time-out on response ca Found #2 errors of type = ERROR ma -4 Device vb timed-out on response. Found #2 errors of type = ERROR ma -4 Device v1 timed-out on response. Found #2 errors of type = ERROR ma -4 Device va timed-out on response. Found #2 errors of type = ERROR ma -4 Device v2 timed-out on response. Found #2 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #2 errors of type = ERROR ma -4 Device v3 timed-out on response. Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #2 errors of type = ERROR ma -4 Device v4 timed-out on response. Found #2 errors of type = ERROR ma -4 Device v5 timed-out on response. Found #2 errors of type = ERROR ma -4 Device v6 timed-out on response. Found #2 errors of type = ERROR ma -4 Device v7 timed-out on response. Found #2 errors of type = ERROR ma -4 Device v8 timed-out on response. Found #2 errors of type = ERROR ma -4 Device v9 timed-out on response. Found #2 errors of type = ERROR ma -4 Device ve timed-out on response. Found #2 errors of type = ERROR ma -4 Device vd timed-out on response. Found #2 errors of type = ERROR ma -4 Device vc timed-out on response. Found #1 errors of type = ERROR ch -4 Device v2 timed-out on response from MATCN Found #1 errors of type = ERROR ma -4 Device i3 timed-out on response. Found #1 errors of type = ERROR ch -4 Device v1 timed-out on response from MATCN Found #1 errors of type = ERROR ch -4 Device v3 timed-out on response from MATCN Found #1 errors of type = ERROR ma -4 Device if timed-out on response. Found #1 errors of type = ERROR ch -4 Device v4 timed-out on response from MATCN Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 44.13 max= 2005.312.17:40:13.05 RX2 min= 39.01 max= 40.96 RX3 min= 0.150 max= 0.152 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= ohig39ft.log.tsy1.ntup nt1= 7 st1= 1u tt= 1 set scale tsys1 [2] min max 63.2 109.0 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 34.7 ymax 110 in match_chan ft1= ohig39ft.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 63.2 109.0 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 59.1 ymax 113.6 in match_chan ft1= ohig39ft.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 63.2 109.0 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 30.3 ymax 82.1