Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 7059600 Found #73 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #52 errors of type = ERROR ch -308 v2 total power integrator overflow Found #51 errors of type = ERROR ch -308 v7 total power integrator overflow Found #8 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #4 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #3 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #2 errors of type = ERROR ch -308 v3 total power integrator overflow Found #2 errors of type = ERROR m5 -904 MARK5 return code 4: error encountered (during attempt to execute) Found #2 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #2 errors of type = ERROR ch -308 v1 total power integrator overflow Found #2 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #1 errors of type = ERROR m5 -900 Can't get SS version Found #1 errors of type = ERROR m5 -900 Previous recording still active Found #1 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #1 errors of type = ERROR qi -202 IF2 attenuator must be MAX OLD or between 0 and 63 Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR m5 -900 Can't get device info Found #1 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #1 errors of type = ERROR m5 -900 Data transfer in progress Found #1 errors of type = ERROR m5 -900 Not while recording or playing Found these BBCs: vc01 vc02 vc05 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 02 05 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= euro75eb.log.tsy1.ntup nt1= 7 st1= 1u tt= 1 set scale tsys1 [2] min max 9.8 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 4.7 ymax 305 in match_chan ft1= euro75eb.log.tsy1.ntup nt1= 8 st1= 2u tt= 1 set scale tsys1 [2] min max 9.8 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 5 ymax 305 in match_chan ft1= euro75eb.log.tsy1.ntup nt1= 11 st1= 5u tt= 1 set scale tsys1 [2] min max 9.8 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 4.7 ymax 305