Starting generation of Calibration File FS version = 0009.0004.0018 time_zero = 6541200 Rack type is MK3/4 Found #227 errors of type = ERROR q+ -201 if3 attenuation must be one of 0 ... 63 max or old. Found #227 errors of type = ERROR qi -201 IF1 attenuator must be MAX OLD or between 0 and 63 Found #226 errors of type = ERROR qs -306 WARNING: ANTCN not being run antenna device is dev null. Found #226 errors of type = ERROR qo -302 WARNING: ANTCN not being run antenna device is dev null. Found #222 errors of type = ERROR qd -301 Synch block CRC checksum test FAILED. Found #98 errors of type = ERROR ch -311 IF distributor is not in remote Found #91 errors of type = ERROR ch -345 Tape drive alarm is on Found #69 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #66 errors of type = ERROR ch -4 Device rx timed-out on response from MATCN Found #64 errors of type = ERROR ch -301 v9 module is not in remote Found #63 errors of type = ERROR ch -301 v8 module is not in remote Found #63 errors of type = ERROR ch -301 v7 module is not in remote Found #39 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #34 errors of type = ERROR ch -309 v5 alarm is on Found #30 errors of type = ERROR ch -329 Formatter time does not agree with Field System time. Found #12 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #11 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #11 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #10 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #9 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #4 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #3 errors of type = ERROR ch -342 Tape is not in ready state (vacuum not ready) Found #3 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #3 errors of type = ERROR ch -327 Formatter's run set switch is in SET position Found #3 errors of type = ERROR ch -309 v8 alarm is on Found #3 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #2 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. Found #2 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #2 errors of type = ERROR ch -309 v9 alarm is on Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #2 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #2 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #2 errors of type = ERROR ch -321 Formatter input does not check with requested setting Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #2 errors of type = ERROR ch -325 Formatter synch test fail Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #2 errors of type = ERROR ch -322 Formatter mode does not check with requested setting Found #1 errors of type = ERROR qg -304 Track 19 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 5 sync errors exceed threshold. Found these BBCs: NBBC: 0 Found these RX parameters: lo dcal lo5mhz RX1 min= 100000 max= 2005.075.17:44:44.86 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: NTSYS: 0