Starting generation of Calibration File FS version = 0009.0006.0002 time_zero = 16736400 Found #170 errors of type = ERROR ch -199 h1 communication trouble turning on lvdt Found #170 errors of type = ERROR ma -4 Device h1 timed-out on response. Found #169 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #121 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #96 errors of type = ERROR ch -4 Device t1 timed-out on response from MATCN Found #92 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #81 errors of type = ERROR ch -342 Tape is not in ready state (vacuum not ready) Found #64 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #64 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #64 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #64 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #35 errors of type = ERROR ch -338 Reproduce equalizer does not check with request Found #35 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #35 errors of type = ERROR ch -337 Reproduce bandwidth does not check with request Found #25 errors of type = ERROR ch -341 Reproduce track B does not check with request Found #25 errors of type = ERROR ch -340 Reproduce track A does not check with request Found #24 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #22 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #21 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #18 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #17 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #17 errors of type = ERROR ch -345 Tape drive alarm is on Found #15 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #14 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #13 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #13 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #13 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #12 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #11 errors of type = ERROR ma -4 Device t1 timed-out on response. Found #11 errors of type = ERROR ch -339 Bypass mode does not check with requested setting Found #10 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #10 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #10 errors of type = ERROR ch -332 Tape drive is not in remote Found #9 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. Found #9 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #8 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #8 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #7 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. Found #7 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #7 errors of type = ERROR qg -304 Track 21 sync errors exceed threshold. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #5 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #5 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #5 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #5 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #5 errors of type = ERROR q< -301 Vacuum is not ready. Found #4 errors of type = ERROR qg -304 Track 15 sync errors exceed threshold. Found #3 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #3 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 65K. Found #3 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #3 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 30K. Found #3 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #2 errors of type = ERROR ch -346 Record enable is in the wrong state. Found #2 errors of type = ERROR ch -364 IF3 switch 1 setting does not check with request. Found #2 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #1 errors of type = ERROR qg -304 Track 17 sync errors exceed threshold. Found #1 errors of type = ERROR ch -308 va total power integrator overflow Found #1 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 43.52 max= 45.60 RX2 min= 38.40 max= 40.47 RX3 min= 0.147 max= 0.150 Plotting 3 Tsys channels: 01 05 09 Tsys1 values are: etc Tsys2 values are: etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= nt1= st1= tt= set scale tsys1 [2] min max set scale tsys2 [2] min max set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100