Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 23212800 Found #351 errors of type = ERROR ch -4 Device rx timed-out on response from MATCN Found #188 errors of type = ERROR ma -4 Device rx timed-out on response. Found #55 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #55 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #54 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #50 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #45 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #45 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #45 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #43 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #42 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #42 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #41 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #40 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #39 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #38 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #38 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #36 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #33 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #14 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #11 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #11 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #6 errors of type = ERROR ch -371 IF3 alarm is on Found #2 errors of type = ERROR ch -309 v5 alarm is on Found #2 errors of type = ERROR ch -368 IF3 frequency does not check with equip.ctl value. Found #2 errors of type = ERROR m5 -903 MARK5 return code 3: syntax (or parameter error) Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #2 errors of type = ERROR m5 -900 Must have ' ' or ' ' Found #2 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 30K. Found #2 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR ch -360 IF3 module shows the majority of possible error conditions Found #1 errors of type = ERROR ch -301 v5 module is not in remote Found #1 errors of type = ERROR ch -308 vb total power integrator overflow Found #1 errors of type = ERROR ch -301 v8 module is not in remote Found #1 errors of type = ERROR ch -365 IF3 switch 2 setting does not check with request. Found #1 errors of type = ERROR ch -361 IF3 module is not in remote Found #1 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 70K. Found #1 errors of type = ERROR ch -363 IF3 mixer state does not check with request. Found #1 errors of type = ERROR ch -364 IF3 switch 1 setting does not check with request. Found #1 errors of type = ERROR ch -362 IF3 attenuator does not check with requested value. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 02 06 11 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= c0514wz.log.tsy1.ntup nt1= 8 st1= 2u tt= 1 set scale tsys1 [2] min max 38.3 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 37.4 ymax 305 in match_chan ft1= c0514wz.log.tsy1.ntup nt1= 20 st1= 6u tt= 1 set scale tsys1 [2] min max 38.3 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 30.3 ymax 305 in match_chan ft1= c0514wz.log.tsy1.ntup nt1= 14 st1= bu tt= 1 set scale tsys1 [2] min max 38.3 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 35.2 ymax 305