Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 22608000 Found #922 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #248 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #22 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #12 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #4 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #3 errors of type = ERROR ma -4 Device vb timed-out on response. Found #2 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #2 errors of type = ERROR qn -201 Error in request. Unknown module or does not match your equipment. Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #1 errors of type = ERROR qz -209 PATCH has not setup the specified VC for FIVPT. Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= c0507on.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 101.4 152.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 101.9 ymax 168.6 in match_chan ft1= c0507on.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 101.4 152.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 90.1 ymax 152.7 in match_chan ft1= c0507on.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 101.4 152.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 107.7 ymax 233