Starting generation of Calibration File 
FS version = 0009.0004.0006 
time_zero = 6937200 
Rack type is MK3/4
Rack type is MK3/4
Found #269 errors of type = ERROR rz  -32 E-- STAT_BADSTNDELAY: Station delay measurement does not match setting.\n 
Found #268 errors of type = ERROR rz  -32 occurred a total of 2 times  but has now stopped 
Found #149 errors of type = ERROR ma   -4 Device vf timed-out on response. 
Found #26 errors of type = ERROR ch -499 measured delay not ZERO  actual value 31 nanseconds 
Found #17 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. 
Found #15 errors of type = ERROR ch -317 Total power integrator overflow on IF2 
Found #12 errors of type = ERROR rl -133 Communications timeout  RCL device probably dead on device rc 
Found #9 errors of type = ERROR ch -370 Total power integrator overflow on IF3 
Found #7 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. 
Found #6 errors of type = ERROR rz  -33 E-C STAT_UICVERFAIL: UI verifier shows failure condition. In C1TEST mode \nthis indicates C1 cable connection fault.\n 
Found #3 errors of type = ERROR rz  -33 occurred a total of 2 times  but has now stopped 
Found #2 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. 
Found #2 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! 
Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. 
Found #2 errors of type = ERROR ch -513 Record data valid flag does not agree with request. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. 
Found #1 errors of type = ERROR rz  -20 EFC STAT_TRANTPMOTFAIL: Transport 4 tape motion sanity check failed\n 
Found #1 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. 
Found #1 errors of type = ERROR rz  -72 occurred a total of 7 times  but has now stopped 
Found #1 errors of type = ERROR rz  -57 occurred a total of 12 times  but has now stopped 
Found #1 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. 
Found #1 errors of type = ERROR rz  -57 EF- STAT_INSTATE: Tape motion state is inconsistent or illegal.\n 
Found #1 errors of type = ERROR rl  -56 Tape motion state is inconsistent or illegal 
Found #1 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. 
Found #1 errors of type = ERROR rd -201 Data valid flag must be "on" or "off". 
Found #1 errors of type = ERROR rz  -72 EF- STAT_BADAGCLEV: Transport 4 AGC levels are outside acceptable range.\n 
Found #1 errors of type = ERROR rz  -54 E-C STAT_TRANLKLOSS: Transport 4 servo lost lock or glitched momentarily.\n 
Found #1 errors of type = ERROR rz  -52 EFC STAT_RPMONILSTATE: Encountered unexpected transport state change during\nautomatic record (state: inconsistent illegal  transport 4).\n 
Found #1 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. 
Found #1 errors of type = ERROR sp   -4 Unrecognized name (not a function or procedure). 
Found #1 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. 
Found these BBCs: vc06 vc11 vc06
NBBC: 3
Found these RX parameters: 02(lo) 03(dcal) 0E(lo5mhz)
RX1 min= 36.08 max= 2000.080.07:22:16.71
RX2 min= 46.45 max= 47.92
RX3 min= 1.021 max= 1.029
Plotting 3 Tsys channels: 06 11 06
Tsys1 values are: 1 2 etc
Tsys2 values are: 9 10 etc
Tsys3 values are:   etc
NTSYS: 3
in match_chan ft1= syw009ho.log.tsy1.ntup nt1= 12 st1= v6 tt= 1
set scale tsys1 [2] min max -5 305
set scale tsys2 [2] min max 57.9 305
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 38.3 ymax 305 
in match_chan ft1= syw009ho.log.tsy2.ntup nt1= 9 st1= v11 tt= 2
set scale tsys1 [2] min max -5 305
set scale tsys2 [2] min max 57.9 305
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 52.9 ymax 305 
in match_chan ft1= syw009ho.log.tsy1.ntup nt1= 12 st1= v6 tt= 1
set scale tsys1 [2] min max -5 305
set scale tsys2 [2] min max 57.9 305
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 38.3 ymax 305