Starting generation of Calibration File FS version = 0009.0004.0013 time_zero = 16308000 Rack type is MK3/4 Found #27 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #27 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #13 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #13 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #9 errors of type = ERROR st -7 Antenna off-source! Found #4 errors of type = ERROR qg -303 Track 2 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 14 parity errors exceed threshold. Found #1 errors of type = ERROR sc -2 setcl: formatter time out-of-range Found #1 errors of type = ERROR st -6 Antenna control restored. Found #1 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #1 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #1 errors of type = ERROR qg -303 Track 33 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 30. Found #1 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 30 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 22 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 31 parity errors exceed threshold. Found #1 errors of type = ERROR st -4 Interface not set to remote. Found #1 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these SK parameters: 00(BXFNT) 02(LO_TMP) 03(DCAL_T) RX1 min= -50.70 max= 2000.188.18:46:06.84 RX2 min= -45.70 max= -1 RX3 min= -46.30 max= -1 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: 5 6 etc NTSYS: 3 in match_chan ft1= rdv22ny.log.tsy1.ntup nt1= 8 st1= v2 tt= 1 set scale tsys1 [2] min max 56.5 305 set scale tsys2 [2] min max 34.3 131.5 set scale tsys3 [2] min max 47.4 261.2 set scale tsys4 [2] min max Tsys scale ymin 54 ymax 305 in match_chan ft1= rdv22ny.log.tsy3.ntup nt1= 8 st1= v6 tt= 3 set scale tsys1 [2] min max 56.5 305 set scale tsys2 [2] min max 34.3 131.5 set scale tsys3 [2] min max 47.4 261.2 set scale tsys4 [2] min max Tsys scale ymin 48.7 ymax 305 in match_chan ft1= rdv22ny.log.tsy2.ntup nt1= 9 st1= v11 tt= 2 set scale tsys1 [2] min max 56.5 305 set scale tsys2 [2] min max 34.3 131.5 set scale tsys3 [2] min max 47.4 261.2 set scale tsys4 [2] min max Tsys scale ymin 29.3 ymax 136.5