Starting generation of Calibration File 
FS version = 0009.0004.0014 
time_zero = 27622800 
Rack type is MK3/4
Rack type is MK3/4
Found #56 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than  35K. 
Found #56 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than  70K. 
Found #42 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track  3 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track  1 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track  7 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track  5 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track  9 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. 
Found #42 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. 
Found #40 errors of type = ERROR qg -304 Track 21 sync errors exceed threshold. 
Found #40 errors of type = ERROR qg -304 Track 17 sync errors exceed threshold. 
Found #39 errors of type = ERROR qg -304 Track 15 sync errors exceed threshold. 
Found #33 errors of type = ERROR qg -304 Track 25 sync errors exceed threshold. 
Found #24 errors of type = ERROR qg -304 Track  5 sync errors exceed threshold. 
Found #24 errors of type = ERROR qg -304 Track 11 sync errors exceed threshold. 
Found #23 errors of type = ERROR qg -304 Track  3 sync errors exceed threshold. 
Found #23 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks 
Found #21 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. 
Found #20 errors of type = ERROR qg -304 Track  7 sync errors exceed threshold. 
Found #20 errors of type = ERROR qg -304 Track 19 sync errors exceed threshold. 
Found #17 errors of type = ERROR qg -304 Track 23 sync errors exceed threshold. 
Found #14 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. 
Found #13 errors of type = ERROR qg -304 Track 27 sync errors exceed threshold. 
Found #12 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. 
Found #10 errors of type = ERROR qg -304 Track 13 sync errors exceed threshold. 
Found #10 errors of type = ERROR qg -305 AUX data differs from expected value on track  5. 
Found #10 errors of type = ERROR qg -304 Track  9 sync errors exceed threshold. 
Found #9 errors of type = ERROR qg -304 Track  1 sync errors exceed threshold. 
Found #8 errors of type = ERROR qg -305 AUX data differs from expected value on track  9. 
Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track  7. 
Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. 
Found #6 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. 
Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. 
Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. 
Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. 
Found #4 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. 
Found #4 errors of type = ERROR qg -305 AUX data differs from expected value on track  1. 
Found #3 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. 
Found #3 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. 
Found #3 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! 
Found #3 errors of type = ERROR qg -305 AUX data differs from expected value on track  3. 
Found #3 errors of type = ERROR an -103 Pointing computer tracking errors are too large. 
Found #3 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. 
Found #2 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. 
Found #1 errors of type = ERROR qa -201 Tape number must be 8 charaters. 
Found #1 errors of type = ERROR ch -334 Tape should be moving and it's stopped 
Found #1 errors of type = ERROR ch -317 Total power integrator overflow on IF2 
Found these BBCs: vc06 vc11 vc06
NBBC: 3
Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ)
RX1 min= -250.0 max= 2000.319.17:47:00.84
RX2 min= -250.0 max= -1
RX3 min= -2.500 max= -1
Plotting 3 Tsys channels: 06 11 06
Tsys1 values are: 1 2 etc
Tsys2 values are: 9 10 etc
Tsys3 values are:   etc
NTSYS: 3
in match_chan ft1= na394ft.log.tsy1.ntup nt1= 12 st1= v6 tt= 1
set scale tsys1 [2] min max 50.6 84.6
set scale tsys2 [2] min max 305 305
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 42.4 ymax 82.6 
in match_chan ft1= na394ft.log.tsy2.ntup nt1= 9 st1= v11 tt= 2
set scale tsys1 [2] min max 50.6 84.6
set scale tsys2 [2] min max 305 305
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 300 ymax 305 
in match_chan ft1= na394ft.log.tsy1.ntup nt1= 12 st1= v6 tt= 1
set scale tsys1 [2] min max 50.6 84.6
set scale tsys2 [2] min max 305 305
set scale tsys3 [2] min max  
set scale tsys4 [2] min max  
 Tsys scale ymin 42.4 ymax 82.6