WACO Correlator Report for NEOS-A-385 (exp# 8385) Obs: 12 September 2000 Correlated: 15 Sep - 21 Sep 2000 Exported: 21 September 2000 Algonquin(G)- - - Late on source on a few scans. Last S-band channel (freq f) is depressed in amp and PC by 10-20% on about 10% of the scans. Fortaleza(F)- - - Did not observe - cryo problem. Gilcreek(A) - - - No problems, Y axis repaired since na383. Kokee(K)- - - - - No problems. Wettzell(V) - - - No problems. S-band delay rate residuals show ionospheric disturbance on baselines: GK AK AV GA Reprocessing: 127 scans = 26% (problem with Phase Cal Module necessitated extra reprocessing) PROCESSING SUMMARY (letter codes not available) *Base 0 1 2 3 4 5 6 7 8 9 N Tot GA X 1 0 0 0 0 1 2 25 48 56 1 134 GA S 1 0 0 0 0 2 6 31 35 58 1 134 GK X 1 0 0 0 0 0 0 31 35 66 1 134 GK S 1 0 0 0 0 0 1 36 38 57 1 134 GV X 0 0 0 1 0 2 3 48 28 50 0 132 GV S 1 0 1 0 0 0 2 30 23 75 0 132 AK X 2 1 1 1 0 1 3 24 37 172 2 244 AK S 2 0 2 1 0 2 2 19 41 173 2 244 AV X 2 0 0 0 0 1 1 22 34 79 0 139 AV S 2 0 0 0 0 3 3 7 15 109 0 139 KV X 1 0 0 1 0 0 0 15 5 61 2 85 KV S 3 1 0 0 0 0 1 7 3 68 2 85 * Column Totals, numbers then percentages 17 2 4 4 0 12 24 295 3421024 12 1736 * % 1.0 .1 .2 .2 0.0 .7 1.4 >->-> 95.7 .7