WACO Correlator Report for NEOS-A-381 (exp# 8381) Obs: 15 August 2000 Correlated: 21 Aug - 25 Aug 2000 Exported: 25 August 2000 Algonquin(G)- - - Tape parity errors higher than normal, still readable. At 229-0200 the highest S-band freq began to drop in correlated amplitude and phase cal amp. After several hours it was less than 50%. This freq was dropped in fourfit on all G baselines. Fortaleza(F)- - - Continues to miss scans because of Field System crashes. Tape parity errors are getting worse. Tracks 10-19 are bad both forward and reverse. Tracks 10,14,16 are not readable (forward) Drop freq d,f in S-band and n in X-band. Gilcreek(A) - - - No observation - hydralic system failure. Kokee(K)- - - - - Kokee repaired a problem with track 10 (freq n) that affected the intensives before this session. Wettzell(V) - - - Two scans missed at 229-0330 S-band delay rate residuals show ionospheric disturbance on baselines: GF FK FV Reprocessing: 192 scans = 49% (high reprocessing because of high error rates on F an G) PROCESSING SUMMARY (letter codes not available) *Base 0 1 2 3 4 5 6 7 8 9 N Tot GF X 3 3 5 1 1 6 10 26 21 51 1 128 GF S 1 0 1 3 5 4 6 16 27 64 1 128 GK X 2 2 1 0 0 3 4 20 17 55 2 106 GK S 2 0 0 2 1 4 4 22 18 52 1 106 GV X 0 2 1 0 2 3 5 43 29 44 2 131 GV S 0 0 2 0 3 2 2 27 29 64 2 131 FK X 1 0 0 0 0 1 3 8 5 28 0 46 FK S 2 0 0 0 0 1 1 2 7 33 0 46 FV X 0 3 1 1 2 4 7 30 28 76 1 153 FV S 10 0 0 1 3 3 4 9 21 101 1 153 KV X 0 1 0 0 0 2 2 14 10 38 0 67 KV S 6 0 0 1 0 0 0 10 5 45 0 67 * Column Totals, numbers then percentages 27 11 11 9 17 33 48 227 217 651 11 1262 * % 2.1 .9 .9 .7 1.3 2.6 3.8 >->-> 86.8 .9