WACO Correlator Report for NEOS-A-380 (exp# 8380) Obs: 8 August 2000 Correlated: 16 Aug - 21 Aug 2000 Exported: 22 August 2000 Algonquin(G)- - - No problems. Fortaleza(F)- - - Continues to miss scans because of Field System crashes. Tape parity errors too high on tracks 14,16 = S-band freq 12,13 in forward direction - these freq dropped in fourfitting. Started late, 221-1911. Vacuum loss and footage problems 222-0330 to 0430. Sband is hard hit because of ionosphere disturbances as well as being down to 4 frequencies. Kokee(K)- - - - - No problems. The track 10 problem seen on the intensives did not affect this session. Ny Alesund(O) - - Tape arrived late (Weds). Phase cal was missing on one scan, 221-1810, but present and stable on all other scans. Wettzell(V) - - - No problems. S-band delay rate residuals show ionospheric disturbance on baselines: GK KO FO FV GF FK Reprocessing: 105 scans = 18% PROCESSING SUMMARY (letter codes not available) *Base 0 1 2 3 4 5 6 7 8 9 N Tot GF X 2 0 0 1 1 1 6 27 14 66 1 119 GF S 4 0 0 0 2 0 0 10 17 85 1 119 GK X 5 2 0 0 0 0 8 38 26 85 1 165 GK S 5 1 0 0 1 0 0 39 32 86 1 165 GO X 0 1 0 0 0 0 0 24 27 60 3 115 GO S 0 0 0 0 1 0 2 22 28 59 3 115 GV X 0 0 0 0 0 1 2 30 18 59 4 114 GV S 0 1 0 1 0 0 1 19 25 63 4 114 FK X 6 0 0 1 0 1 1 5 10 34 2 60 FK S 9 0 0 1 0 0 1 3 5 39 2 60 FO X 7 2 1 1 0 0 2 5 13 47 1 79 FO S 9 0 0 1 0 1 2 3 5 57 1 79 FV X 7 2 0 0 0 4 6 17 20 86 3 145 FV S 13 0 1 0 0 1 1 1 7 118 3 145 KO X 7 1 1 1 0 0 4 27 18 118 0 177 KO S 9 1 1 1 0 0 1 10 17 137 0 177 KV X 6 0 0 1 1 0 2 6 14 58 1 89 KV S 7 0 1 0 1 0 0 4 6 69 1 89 OV X 4 0 0 0 1 0 1 26 26 150 1 209 OV S 5 0 0 1 0 0 1 10 18 173 1 209 * Column Totals, numbers then percentages 105 11 5 10 8 9 41 326 3461649 34 2544 * % 4.1 .4 .2 .4 .3 .4 1.6 >->-> 91.2 1.3