Starting generation of Calibration File FS version = 0009.0004.0008 time_zero = 16218000 Rack type is MK3/4 Rack type is MK3/4 Found #11 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #10 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #9 errors of type = ERROR sc -3 setcl: reseting system clock failed. Found #7 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 30K. Found #5 errors of type = ERROR ST -4 Error in antenna communication Found #4 errors of type = ERROR ch -306 vf LSB attenuator does not check with requested setting Found #4 errors of type = ERROR ch -304 vf TPI selection does not check with requested setting Found #3 errors of type = ERROR ch -4 Device v1 timed-out on response from MATCN Found #3 errors of type = ERROR sc -10 setcl: failed too many times time information not updated. Found #3 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #2 errors of type = ERROR ch -309 vf alarm is on Found #2 errors of type = ERROR ch -302 vf frequency does not check with requested value Found #2 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #2 errors of type = ERROR ch -303 vf bandwidth does not check with requested value Found #2 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #2 errors of type = ERROR ch -305 vf USB attenuator does not check with requested setting Found #2 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #1 errors of type = ERROR ch -309 v5 alarm is on Found #1 errors of type = ERROR sc -2 setcl: formatter time out-of-range Found #1 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #1 errors of type = ERROR ch -309 v7 alarm is on Found #1 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #1 errors of type = ERROR ch -309 vc alarm is on Found #1 errors of type = ERROR ch -309 vb alarm is on Found #1 errors of type = ERROR ch -309 v8 alarm is on Found #1 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 35.59 max= 2000.187.17:24:48.61 RX2 min= 47.07 max= 47.92 RX3 min= 2.500 max= 2.500 Can't plot RX3 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= na375wz.log.tsy1.ntup nt1= 8 st1= v2 tt= 1 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max -5 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 28.8 ymax 305 in match_chan ft1= na375wz.log.tsy1.ntup nt1= 12 st1= v6 tt= 1 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max -5 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 30.7 ymax 305 in match_chan ft1= na375wz.log.tsy2.ntup nt1= 9 st1= v11 tt= 2 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max -5 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305