Starting generation of Calibration File FS version = 0009.0004.0005 time_zero = 9478800 Rack type is MK3/4 Found #5 errors of type = ERROR st -7 Antenna off-source! Found #3 errors of type = ERROR ch -309 vb alarm is on Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #1 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #1 errors of type = ERROR q< -301 Vacuum is not ready. Found #1 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #1 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 30 parity errors exceed threshold. Found #1 errors of type = ERROR st -5 Error return from antenna. Found #1 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these SK parameters: 00(BXFNT) 02(LO_TMP) 03(DCAL_T) RX1 min= 22.80 max= 2000.109.17:25:57.63 RX2 min= 47.50 max= 47.70 RX3 min= 45.20 max= 45.30 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: 5 6 etc NTSYS: 3 in match_chan ft1= na364ny.log.tsy1.ntup nt1= 8 st1= v2 tt= 1 set scale tsys1 [2] min max 53.5 204.0 set scale tsys2 [2] min max 26.6 135.8 set scale tsys3 [2] min max 47.4 174.9 set scale tsys4 [2] min max Tsys scale ymin 52.9 ymax 235.8 in match_chan ft1= na364ny.log.tsy3.ntup nt1= 8 st1= v6 tt= 3 set scale tsys1 [2] min max 53.5 204.0 set scale tsys2 [2] min max 26.6 135.8 set scale tsys3 [2] min max 47.4 174.9 set scale tsys4 [2] min max Tsys scale ymin 41 ymax 178.1 in match_chan ft1= na364ny.log.tsy2.ntup nt1= 9 st1= v11 tt= 2 set scale tsys1 [2] min max 53.5 204.0 set scale tsys2 [2] min max 26.6 135.8 set scale tsys3 [2] min max 47.4 174.9 set scale tsys4 [2] min max Tsys scale ymin 21.6 ymax 140.8