Starting generation of Calibration File FS version = 0009.0004.0005 time_zero = 414000 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Found #106 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #33 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #27 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #24 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #23 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #17 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #14 errors of type = ERROR ch -201 hd communication trouble Found #12 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #11 errors of type = ERROR ch -342 Tape is not in ready state (vacuum not ready) Found #9 errors of type = ERROR q< -301 Vacuum is not ready. Found #9 errors of type = ERROR ch -302 vc frequency does not check with requested value Found #9 errors of type = ERROR ch -304 vc TPI selection does not check with requested setting Found #9 errors of type = ERROR ch -303 vc bandwidth does not check with requested value Found #9 errors of type = ERROR ch -309 vc alarm is on Found #8 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #8 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #8 errors of type = ERROR ch -305 vc USB attenuator does not check with requested setting Found #8 errors of type = ERROR ch -306 vc LSB attenuator does not check with requested setting Found #7 errors of type = ERROR q -404 Head positioning failed to converge. Found #7 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #6 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #6 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #6 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #5 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #5 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. Found #5 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #5 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #5 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. Found #3 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #2 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 35K. Found #2 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. Found #2 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #1 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 70K. Found #1 errors of type = ERROR ch -307 vc unlock indicator is on Found #1 errors of type = ERROR q -201 Write head pass number out of range. Found #1 errors of type = ERROR ch -344 Tape should be recording but no tracks are enabled. Found these BBCs: vc06 vc11 vc06 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 44.38 max= 2000.004.19:43:04.37 RX2 min= 79.30 max= 139.1 RX3 min= 0.132 max= 0.139 Plotting 3 Tsys channels: 06 11 06 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= na349ft.log.tsy1.ntup nt1= 12 st1= v6 tt= 1 set scale tsys1 [2] min max 69.3 127.5 set scale tsys2 [2] min max 120.6 172.7 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 61.3 ymax 125.4 in match_chan ft1= na349ft.log.tsy2.ntup nt1= 9 st1= v11 tt= 2 set scale tsys1 [2] min max 69.3 127.5 set scale tsys2 [2] min max 120.6 172.7 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 115.6 ymax 177.7 in match_chan ft1= na349ft.log.tsy1.ntup nt1= 12 st1= v6 tt= 1 set scale tsys1 [2] min max 69.3 127.5 set scale tsys2 [2] min max 120.6 172.7 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 61.3 ymax 125.4