Correlator Notes (B O N N Correlator) IRIS-S 151 No#1566 2000/171 = MON,JUN 19,2000 14:00UT start 2000/172 = TUE,JUN 20,2000 14:00UT stop STATION COMMENTS Gc : lost 14 scans due to local power outage time 171-1600 and 171-1643 Ft : few scans lost due to system problems between time 172-0553 and 172-0631 Hh : no fringes found at x-band, s-band very week reason: x-band beam was not on source, cryogenic package failed Wz : SNR lower than 7 at about 40 scans after time 171-2100 The operator reported "the cooling receiver broke down at about 4:30ut. The compressor was turn off and the receiver got warmer and warmer INTensive break from 14.00 to 16.00UT Wf : normal CLOCK REF CLK SYNC CLK RATE CLK SYNC EPOCH * usec sec/sec yy ddd hh mm f 0.39 0.0 00 000 00 00 *FORTLEZA ref a -6.82 -324.0E-14 00 171 14 00 *GILCREEK am j 0.0 0.0 00 171 14 00 *HARTRAO Not obs. e 3.59 0.0 00 000 00 00 *WESTFORD am v -2.1 0.0 00 000 00 00 *WETTZELL am REFRINGE/CORRELATION nothing refringed STATISTICS: >95% QF 6-9 < 5% QF 0 < 1% QF 1-5,A-N Processing factor(MK4): 3.2 + 0.8 (for recorrelation(rec.track error)) + 0.4 (error Code G) REMARKS * archived files DAT in standard UNIX tar format all data were correlated with MK4 correlator. * up to now database version1 is available at the analysis Center BKG LEIPZIG or on anonymous ftp at mpifr-bonn.mpg.de directory outgoing/mueskens/iriss/iriss151/ regards Mauro/Arno