Starting generation of Calibration File FS version = 0009.0004.0001 time_zero = 910800 Rack type is VLBA Found #29 errors of type = ERROR qk -211 Tsys value for device ia overflowed or were less than zero. Found #8 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #8 errors of type = ERROR st -1 Antenna got the wrong angles Found #7 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #4 errors of type = ERROR ch -208 b8 gain mode does not check with requested setting Found #4 errors of type = ERROR ma -4 Device wx timed-out on response. Found #3 errors of type = ERROR qk -211 Tsys value for device ib overflowed or were less than zero. Found #3 errors of type = ERROR ch -4 Device rx timed-out on response from MATCN Found #2 errors of type = ERROR qk -211 Tsys value for device eu overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device 6u overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device 1u overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device cu overflowed or were less than zero. Found #2 errors of type = ERROR ma -4 Device rx timed-out on response. Found #2 errors of type = ERROR st -2 Commanding antenna failed too many times giving up. Found #2 errors of type = ERROR qk -211 Tsys value for device ic overflowed or were less than zero. Found #1 errors of type = ERROR mc -2 Interface ba responded but did not ACKnowledge. Found #1 errors of type = ERROR qk -211 Tsys value for device 5u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device bu overflowed or were less than zero. Found #1 errors of type = ERROR an -102 Pointing computer command angles are incorrect. Found #1 errors of type = ERROR qk -211 Tsys value for device 2u overflowed or were less than zero. Found #1 errors of type = ERROR mc -2 Interface b8 responded but did not ACKnowledge. Found #1 errors of type = ERROR qk -211 Tsys value for device 3u overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device 7u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 8u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 9u overflowed or were less than zero. Found #1 errors of type = ERROR st -3 Commanding angles okay now. Found these BBCs: bbc02 bbc06 bbc11 NBBC: 3 Found these RX parameters: 00(front) 02(lo) 03(dcal) RX1 min= 15.32 max= 2000.010.13:34:40.40 RX2 min= 44.26 max= 47.43 RX3 min= 44.50 max= 47.31 Plotting 3 Tsys channels: 02 06 11 Tsysa values are: 1 2 3 etc Tsysb values are: 9 10 11 etc Tsysc values are: etc Tsysd values are: etc NTSYS: 3 in match_chan ft1= is146gc.log.tsy1.ntup nt1= 8 st1= 2u tt= 1 set scale tsys1 [2] min max 53.4 305 set scale tsys2 [2] min max -5 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305 in match_chan ft1= is146gc.log.tsy1.ntup nt1= 12 st1= 6u tt= 1 set scale tsys1 [2] min max 53.4 305 set scale tsys2 [2] min max -5 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305 in match_chan ft1= is146gc.log.tsy2.ntup nt1= 9 st1= 11u tt= 2 set scale tsys1 [2] min max 53.4 305 set scale tsys2 [2] min max -5 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305