Starting generation of Calibration File 
FS version = 0009.0004.0000 
time_zero = 21463200 
Rack type is MK3/4
Rack type is MK3/4
Rack type is MK3/4
Rack type is MK3/4
Rack type is MK3/4
Rack type is MK3/4
Rack type is MK3/4
Rack type is MK3/4
Rack type is MK3/4
Rack type is MK3/4
Rack type is MK3/4
Rack type is MK3/4
Found #126 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! 
Found #100 errors of type = ERROR ch -341 Reproduce track B does not check with request 
Found #100 errors of type = ERROR ch -338 Reproduce equalizer does not check with request 
Found #66 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks 
Found #54 errors of type = ERROR ch -352 Tape head 2 is not in requested position. 
Found #48 errors of type = ERROR ch -351 Tape head 1 is not in requested position. 
Found #42 errors of type = ERROR ch -334 Tape should be moving and it's stopped 
Found #22 errors of type = ERROR ma   -4 Device vd timed-out on response. 
Found #16 errors of type = ERROR ma   -4 Device v1 timed-out on response. 
Found #13 errors of type = ERROR ch -346 Record enable is in the wrong state. 
Found #12 errors of type = ERROR ch -344 Tape should be recording  but no tracks are enabled. 
Found #11 errors of type = ERROR ma   -4 Device v8 timed-out on response. 
Found #11 errors of type = ERROR ma   -4 Device v2 timed-out on response. 
Found #11 errors of type = ERROR ma   -4 Device v9 timed-out on response. 
Found #11 errors of type = ERROR ma   -4 Device v5 timed-out on response. 
Found #11 errors of type = ERROR ma   -4 Device v4 timed-out on response. 
Found #11 errors of type = ERROR ma   -4 Device ve timed-out on response. 
Found #11 errors of type = ERROR ma   -4 Device v6 timed-out on response. 
Found #11 errors of type = ERROR ma   -4 Device va timed-out on response. 
Found #11 errors of type = ERROR ma   -4 Device vb timed-out on response. 
Found #11 errors of type = ERROR ma   -4 Device vc timed-out on response. 
Found #11 errors of type = ERROR ma   -4 Device v7 timed-out on response. 
Found #11 errors of type = ERROR ma   -4 Device v3 timed-out on response. 
Found #8 errors of type = ERROR ch -342 Tape is not in ready state (vacuum not ready) 
Found #4 errors of type = ERROR ma   -4 Device if timed-out on response. 
Found #3 errors of type = ERROR ch -332 Tape drive is not in remote 
Found #2 errors of type = ERROR sp   -4 Unrecognized name (not a function or procedure). 
Found #1 errors of type = ERROR sc   -2 setcl: formatter time out-of-range 
Found #1 errors of type = ERROR qi -201 IF1 attenuator must be MAX  OLD  or between 0 and 63 
Found #1 errors of type = ERROR q< -301 Vacuum is not ready. 
Found these BBCs:   
NBBC: 0
Found these  parameters:   
RX1 min= 100000 max= -1
RX2 min= 100000 max= -1
RX3 min= 100000 max= -1
Plotting 0 Tsys channels:   
NTSYS: 0