Starting generation of Calibration File FS version = 0009.0004.0000 time_zero = 21463200 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Found #126 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #100 errors of type = ERROR ch -341 Reproduce track B does not check with request Found #100 errors of type = ERROR ch -338 Reproduce equalizer does not check with request Found #66 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #54 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #48 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #42 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #22 errors of type = ERROR ma -4 Device vd timed-out on response. Found #16 errors of type = ERROR ma -4 Device v1 timed-out on response. Found #13 errors of type = ERROR ch -346 Record enable is in the wrong state. Found #12 errors of type = ERROR ch -344 Tape should be recording but no tracks are enabled. Found #11 errors of type = ERROR ma -4 Device v8 timed-out on response. Found #11 errors of type = ERROR ma -4 Device v2 timed-out on response. Found #11 errors of type = ERROR ma -4 Device v9 timed-out on response. Found #11 errors of type = ERROR ma -4 Device v5 timed-out on response. Found #11 errors of type = ERROR ma -4 Device v4 timed-out on response. Found #11 errors of type = ERROR ma -4 Device ve timed-out on response. Found #11 errors of type = ERROR ma -4 Device v6 timed-out on response. Found #11 errors of type = ERROR ma -4 Device va timed-out on response. Found #11 errors of type = ERROR ma -4 Device vb timed-out on response. Found #11 errors of type = ERROR ma -4 Device vc timed-out on response. Found #11 errors of type = ERROR ma -4 Device v7 timed-out on response. Found #11 errors of type = ERROR ma -4 Device v3 timed-out on response. Found #8 errors of type = ERROR ch -342 Tape is not in ready state (vacuum not ready) Found #4 errors of type = ERROR ma -4 Device if timed-out on response. Found #3 errors of type = ERROR ch -332 Tape drive is not in remote Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR sc -2 setcl: formatter time out-of-range Found #1 errors of type = ERROR qi -201 IF1 attenuator must be MAX OLD or between 0 and 63 Found #1 errors of type = ERROR q< -301 Vacuum is not ready. Found these BBCs: NBBC: 0 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: NTSYS: 0