Starting generation of Calibration File FS version = 0009.0004.0006 time_zero = 11786400 Rack type is VLBA Found #244 errors of type = ERROR qk -211 Tsys value for device ib overflowed or were less than zero. Found #244 errors of type = ERROR qk -211 Tsys value for device ic overflowed or were less than zero. Found #45 errors of type = ERROR ST -2 portopen_: not able to open device Found #43 errors of type = ERROR st -434 Error reading FM offset port. (OFF the 50 Ohm at counter!) Found #9 errors of type = ERROR qo -410 BEAM size must already be defined. Found #7 errors of type = ERROR qk -211 Tsys value for device ia overflowed or were less than zero. Found #7 errors of type = ERROR qg -303 Track 22 parity errors exceed threshold. Found #7 errors of type = ERROR qg -303 Track 18 parity errors exceed threshold. Found #5 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #5 errors of type = ERROR qg -303 Track 30 parity errors exceed threshold. Found #3 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #3 errors of type = ERROR qg -303 Track 14 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 10 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 26 parity errors exceed threshold. Found #2 errors of type = ERROR qo -401 No default for BEAMx until LO has been setup. Found #2 errors of type = ERROR ST -603 Weather station is sending parameters again. Found #2 errors of type = ERROR ST -601 Weather station didn't send parameters. Found #2 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #2 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #1 errors of type = ERROR qk -211 Tsys value for device 8u overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device 9u overflowed or were less than zero. Found #1 errors of type = ERROR vt -201 Tape parameter must be low or off. Found #1 errors of type = ERROR sc -2 setcl: formatter time out-of-range Found #1 errors of type = ERROR qk -211 Tsys value for device 7u overflowed or were less than zero. Found these BBCs: bbc02 bbc06 bbc11 NBBC: 3 Found these RX parameters: 00(BXFNT_) 01(IF_PLT) 03(DCAL_T) RX1 min= 19.60 max= 34.10 RX2 min= 17.40 max= 31.90 RX3 min= 42.80 max= 44.90 Plotting 3 Tsys channels: 02 06 11 Tsysa values are: 1 2 3 etc Tsysb values are: 9 10 11 etc Tsysc values are: etc Tsysd values are: etc NTSYS: 3 in match_chan ft1= euro56tg.log.tsy1.ntup nt1= 7 st1= 2u tt= 1 set scale tsys1 [2] min max 63.1 357.6 set scale tsys2 [2] min max 52.2 253.5 set scale tsys3 [2] min max Tsys scale ymin 63.4 ymax 100 in match_chan ft1= euro56tg.log.tsy1.ntup nt1= 11 st1= 6u tt= 1 set scale tsys1 [2] min max 63.1 357.6 set scale tsys2 [2] min max 52.2 253.5 set scale tsys3 [2] min max Tsys scale ymin 63.8 ymax 100 in match_chan ft1= euro56tg.log.tsy2.ntup nt1= 8 st1= 11u tt= 2 set scale tsys1 [2] min max 63.1 357.6 set scale tsys2 [2] min max 52.2 253.5 set scale tsys3 [2] min max Tsys scale ymin 52.2 ymax 100