Starting generation of Calibration File FS version = 0009.0004.0005 time_zero = 6606000 Rack type is MK3/4 Found #8 errors of type = ERROR st -7 Antenna off-source! Found #2 errors of type = ERROR ch -312 IF1 attenuator does not check with requested value Found #2 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #1 errors of type = ERROR ch -313 IF2 attenuator does not check with requested value Found #1 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 29. Found #1 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #1 errors of type = ERROR st -5 Error return from antenna. Found #1 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #1 errors of type = ERROR bo -105 Error opening schedule file FMP FFF Found #1 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these SK parameters: 00(BXFNT) 02(LO_TMP) 03(DCAL_T) RX1 min= 23.00 max= 23.40 RX2 min= 47.60 max= 47.70 RX3 min= 45.60 max= 45.80 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: 5 6 etc NTSYS: 3 in match_chan ft1= euro55ny.log.tsy1.ntup nt1= 7 st1= v2 tt= 1 set scale tsys1 [2] min max 56.3 91.2 set scale tsys2 [2] min max 29.5 56.9 set scale tsys3 [2] min max 48.5 78.1 Tsys scale ymin 58.1 ymax 94.9 in match_chan ft1= euro55ny.log.tsy3.ntup nt1= 7 st1= v6 tt= 3 set scale tsys1 [2] min max 56.3 91.2 set scale tsys2 [2] min max 29.5 56.9 set scale tsys3 [2] min max 48.5 78.1 Tsys scale ymin 53.7 ymax 86.5 in match_chan ft1= euro55ny.log.tsy2.ntup nt1= 8 st1= v11 tt= 2 set scale tsys1 [2] min max 56.3 91.2 set scale tsys2 [2] min max 29.5 56.9 set scale tsys3 [2] min max 48.5 78.1 Tsys scale ymin 29.5 ymax 56.9