Starting generation of Calibration File FS version = 0009.0004.0002 time_zero = 6606000 Rack type is MK3/4 Found #341 errors of type = ERROR ch -301 vf module is not in remote Found #243 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #214 errors of type = ERROR ch -303 v6 bandwidth does not check with requested value Found #71 errors of type = ERROR ch -309 vf alarm is on Found #70 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #70 errors of type = ERROR ch -307 vf unlock indicator is on Found #58 errors of type = ERROR ch -309 v6 alarm is on Found #53 errors of type = ERROR ch -307 v6 unlock indicator is on Found #19 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #15 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #13 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #10 errors of type = ERROR ch -303 vf bandwidth does not check with requested value Found #10 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #8 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #7 errors of type = ERROR ch -301 v6 module is not in remote Found #6 errors of type = ERROR ch -302 vf frequency does not check with requested value Found #6 errors of type = ERROR ch -304 vf TPI selection does not check with requested setting Found #6 errors of type = ERROR ch -306 vf LSB attenuator does not check with requested setting Found #6 errors of type = ERROR ch -305 vf USB attenuator does not check with requested setting Found #4 errors of type = ERROR ch -4 Device vf timed-out on response from MATCN Found #4 errors of type = ERROR ch -306 v6 LSB attenuator does not check with requested setting Found #4 errors of type = ERROR ch -304 v6 TPI selection does not check with requested setting Found #4 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #3 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #3 errors of type = ERROR ch -305 v6 USB attenuator does not check with requested setting Found #3 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #3 errors of type = ERROR ma -4 Device v6 timed-out on response. Found #3 errors of type = ERROR ch -302 v6 frequency does not check with requested value Found #3 errors of type = ERROR qd -301 Synch block CRC checksum test FAILED. Found #3 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #2 errors of type = ERROR ch -4 Device v6 timed-out on response from MATCN Found #2 errors of type = ERROR ma -4 Device vf timed-out on response. Found #1 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #1 errors of type = ERROR qv -203 TPI must be U L UL IF LO or GR. Found #1 errors of type = ERROR ch -4 Device v7 timed-out on response from MATCN Found #1 errors of type = ERROR ch -4 Device v8 timed-out on response from MATCN Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= euro55ma.log.tsy1.ntup nt1= 7 st1= v2 tt= 1 set scale tsys1 [2] min max 43.4 89.3 set scale tsys2 [2] min max 15.9 99999 set scale tsys3 [2] min max Tsys scale ymin 49.8 ymax 79.5 in match_chan ft1= euro55ma.log.tsy1.ntup nt1= 11 st1= v6 tt= 1 set scale tsys1 [2] min max 43.4 89.3 set scale tsys2 [2] min max 15.9 99999 set scale tsys3 [2] min max Tsys scale ymin 12.1 ymax 83.3 in match_chan ft1= euro55ma.log.tsy2.ntup nt1= 8 st1= v11 tt= 2 set scale tsys1 [2] min max 43.4 89.3 set scale tsys2 [2] min max 15.9 99999 set scale tsys3 [2] min max Tsys scale ymin 15.9 ymax 100