Starting generation of Calibration File FS version = 0009.0004.0006 time_zero = 2372400 Rack type is VLBA Found #202 errors of type = ERROR qs -306 WARNING: ANTCN not being run antenna device is dev null. Found #202 errors of type = ERROR qo -302 WARNING: ANTCN not being run antenna device is dev null. Found #126 errors of type = ERROR qk -211 Tsys value for device ic overflowed or were less than zero. Found #81 errors of type = ERROR ib -306 GPIB(eabo) I O operation aborted WF Found #71 errors of type = ERROR ib -306 GPIB(eabo) I O operation aborted RD Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 16. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 8. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 4. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 20. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 12. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 29. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 28. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #22 errors of type = ERROR qg -305 AUX data differs from expected value on track 24. Found #10 errors of type = ERROR qa -201 Tape number must be 8 charaters. Found #1 errors of type = ERROR qg -303 Track 30 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #1 errors of type = ERROR sc -2 setcl: formatter time out-of-range Found #1 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found these BBCs: NBBC: 0 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: Tsysa values are: 1 2 3 etc Tsysb values are: 9 10 11 etc Tsysc values are: etc Tsysd values are: etc NTSYS: 0