Starting generation of Calibration File FS version = 0009.0004.0006 time_zero = 2372400 Rack type is VLBA Rack type is VLBA Found #272 errors of type = ERROR 4f -503 Rack ID does not have at least two zero bits. Found #244 errors of type = ERROR qk -211 Tsys value for device ib overflowed or were less than zero. Found #244 errors of type = ERROR qk -211 Tsys value for device ic overflowed or were less than zero. Found #150 errors of type = ERROR ST -23 portread_: timeout in acu-communication Found #120 errors of type = ERROR ST -111 acu_command: OFFS Found #30 errors of type = ERROR ST -122 acu_command: GETA Found #9 errors of type = ERROR qo -410 BEAM size must already be defined. Found #6 errors of type = ERROR bo -129 Error in new proc routine stack is flushed. FMP FFF Found #6 errors of type = ERROR ST -2 portopen_: not able to open device Found #5 errors of type = ERROR qg -303 Track 4 parity errors exceed threshold. Found #5 errors of type = ERROR qg -303 Track 28 parity errors exceed threshold. Found #5 errors of type = ERROR qg -303 Track 18 parity errors exceed threshold. Found #4 errors of type = ERROR qg -303 Track 24 parity errors exceed threshold. Found #4 errors of type = ERROR qg -303 Track 20 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 8 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 12 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 22 parity errors exceed threshold. Found #3 errors of type = ERROR st -434 Error reading FM offset port. (OFF the 50 Ohm at counter!) Found #3 errors of type = ERROR qo -401 No default for BEAMx until LO has been setup. Found #3 errors of type = ERROR qg -303 Track 16 parity errors exceed threshold. Found #3 errors of type = ERROR ST -603 Weather station is sending parameters again. Found #3 errors of type = ERROR qg -303 Track 26 parity errors exceed threshold. Found #3 errors of type = ERROR ST -601 Weather station didn't send parameters. Found #2 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #2 errors of type = ERROR qk -211 Tsys value for device du overflowed or were less than zero. Found #2 errors of type = ERROR qz -414 Detector device 1 not one of ifa ... ifd or bbc1 ... bbc14. Found #2 errors of type = ERROR qg -303 Track 29 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 30 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 10 parity errors exceed threshold. Found #2 errors of type = ERROR 4f -501 Formatter was failing the synch test. Found #2 errors of type = ERROR qg -303 Track 6 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 31 parity errors exceed threshold. Found #2 errors of type = ERROR qk -211 Tsys value for device eu overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device 2u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 8u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 6u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device ia overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device cu overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 1u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 4u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 3u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 5u overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #1 errors of type = ERROR sp -1 Error in characters following a ! Found #1 errors of type = ERROR qa -201 Tape number must be 8 charaters. Found #1 errors of type = ERROR ma -2 Illegal mode Found #1 errors of type = ERROR qk -211 Tsys value for device 7u overflowed or were less than zero. Found #1 errors of type = ERROR ch -233 rc tape drive should be moving and it isn't Found #1 errors of type = ERROR qk -211 Tsys value for device au overflowed or were less than zero. Found #1 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR qk -211 Tsys value for device bu overflowed or were less than zero. Found these BBCs: bbc02 bbc06 bbc11 NBBC: 3 Found these RX parameters: 00(BXFNT_) 01(IF_PLT) 03(DCAL_T) RX1 min= 6.400 max= 16.10 RX2 min= 3.800 max= 16.80 RX3 min= 35.50 max= 42.60 Plotting 3 Tsys channels: 02 06 11 Tsysa values are: 1 2 3 etc Tsysb values are: 9 10 11 etc Tsysc values are: etc Tsysd values are: etc NTSYS: 3 in match_chan ft1= euro53tg.log.tsy1.ntup nt1= 7 st1= 2u tt= 1 set scale tsys1 [2] min max 56.2 9519.0 set scale tsys2 [2] min max 41.9 300.2 set scale tsys3 [2] min max Tsys scale ymin 57.5 ymax 74.3 in match_chan ft1= euro53tg.log.tsy1.ntup nt1= 11 st1= 6u tt= 1 set scale tsys1 [2] min max 56.2 9519.0 set scale tsys2 [2] min max 41.9 300.2 set scale tsys3 [2] min max Tsys scale ymin 56.9 ymax 100 in match_chan ft1= euro53tg.log.tsy2.ntup nt1= 8 st1= 11u tt= 2 set scale tsys1 [2] min max 56.2 9519.0 set scale tsys2 [2] min max 41.9 300.2 set scale tsys3 [2] min max Tsys scale ymin 41.9 ymax 100