Starting generation of Calibration File FS version = 0009.0004.0006 time_zero = 24494400 Rack type is MK3/4 Rack type is MK3/4 Found #264 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #185 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #59 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #31 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #28 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #19 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #16 errors of type = ERROR ch -341 Reproduce track B does not check with request Found #16 errors of type = ERROR ch -340 Reproduce track A does not check with request Found #14 errors of type = ERROR ch -332 Tape drive is not in remote Found #12 errors of type = ERROR q -404 Head positioning failed to converge. Found #11 errors of type = ERROR ch -338 Reproduce equalizer does not check with request Found #11 errors of type = ERROR ch -337 Reproduce bandwidth does not check with request Found #9 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #8 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #8 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #8 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #7 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #7 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #7 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #5 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #5 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #4 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #4 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #4 errors of type = ERROR qg -304 Track 13 sync errors exceed threshold. Found #4 errors of type = ERROR qd -301 Synch block CRC checksum test FAILED. Found #4 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #3 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #3 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #3 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #3 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 27 sync errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #1 errors of type = ERROR ib -4 GPIB Device time-out on response g1 Found #1 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #1 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #1 errors of type = ERROR ib -302 GPIB(enol) write handshake error CHECK instrument and cable W1 Found these BBCs: vc06 vc11 vc06 NBBC: 3 Found these RX parameters: 00(front) 01(rear) 02(lo) RX1 min= 11.29 max= 2000.283.12:36:18.49 RX2 min= 24.23 max= 30.70 RX3 min= 35.34 max= 39.49 Plotting 3 Tsys channels: 06 11 06 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= cohg13ho.log.tsy1.ntup nt1= 12 st1= v6 tt= 1 set scale tsys1 [2] min max -5 94.5 set scale tsys2 [2] min max -5 94.5 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 84.4 in match_chan ft1= cohg13ho.log.tsy2.ntup nt1= 9 st1= v11 tt= 2 set scale tsys1 [2] min max -5 94.5 set scale tsys2 [2] min max -5 94.5 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 99.5 in match_chan ft1= cohg13ho.log.tsy1.ntup nt1= 12 st1= v6 tt= 1 set scale tsys1 [2] min max -5 94.5 set scale tsys2 [2] min max -5 94.5 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 84.4