Starting generation of Calibration File FS version = 0009.0004.0006 time_zero = 3330000 Rack type is MK3/4 Found #306 errors of type = ERROR ma -4 Device vf timed-out on response. Found #188 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #80 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #56 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #55 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #36 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #19 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #9 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #6 errors of type = ERROR ch -201 hd communication trouble Found #6 errors of type = ERROR q -404 Head positioning failed to converge. Found #5 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #2 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #2 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #1 errors of type = ERROR ch -348 Receiver LO is unlocked. Found #1 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found these BBCs: vc06 vc11 NBBC: 2 Found these RX parameters: 00(front) 01(rear) 02(lo) RX1 min= 17.15 max= 2000.038.13:26:28.63 RX2 min= 31.68 max= 44.87 RX3 min= 39.13 max= 52.44 Plotting 2 Tsys channels: 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 2 in match_chan ft1= cohg11ho.log.tsy1.ntup nt1= 12 st1= v6 tt= 1 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max -5 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305 in match_chan ft1= cohg11ho.log.tsy2.ntup nt1= 9 st1= v11 tt= 2 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max -5 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305