Correlator Notes (B O N N Correlator) COHIG11-00 No#1557 2000/038 = MON,FEB 07,2000 start 2000/039 = TUE,FEB 08,2000 start STATION COMMENTS Ho : Pay TV interferences found in S-band freq. 2322 amp and phase cal volt. reduced by 40-60% refringed without this freq. Kk : looks normal, no manual phase cal used Ft : X-band freq. 8182 Index 1 (ref.freq.) missed Hh : no data observed between 038-1910 to 038-2207 reason unknown - no comment found in log file Oh : - phase cal voltage something to high (100-180) manual phase cal used - from the beginning to ~038-2000 I notified in two freq. 8562 + 8862 (x-band) phase offsets of around 200 deg. sporadicly and not both at the same time - reason unknown CLOCK REF CLK SYNC CLK RATE CLK SYNC EPOCH * usec sec/sec yy ddd hh mm usec f 0.16 0.0 0 0 0 0 *FORTLEZA ref j -10.80 -120.0E-14 00 038 18 22 *HARTRAO ok h -2.23 -850.0E-14 00 039 11 34 *HOBART26 ok k 0.65 0.0 00 038 14 47 *KOKEE ok p -0.02 -240.0E-14 00 038 14 47 *OHIGGINS ok REFRINGE/RECORRELATION if station F and f_group X freqs bcdefgh if station H and f_group S freqs ijklm if station P and f_group X freqs abcdefgh pc_mode manual pc_phases abcdefgh 87 -162 160 132 107 131 -118 145 if station P and f_group S freqs ijklmn pc_mode manual pc_phases ijklmn -83 -88 -157 -64 -92 -113 STATISTICS: ~10 % not processed (Hh) >80 % QF 6-9 <9 % QF 0,N <1 % QF 1-5,A-F Processing factor: 3.3 (MK3A) REMARKS * archived files DAT in standard UNIX tar format #01 AF087 #2 AF089 #03 complete data incl. logfiles etc * up to now database version1 is available at the analysis Center BKG LEIPZIG or on anonymous ftp at ftp.mpifr-bonn.mpg.de directory outgoing/mueskens/cohig/cohig11/ regards Arno