Starting generation of Calibration File FS version = 0009.0004.0006 time_zero = 9478800 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Found #38 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #28 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #10 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #9 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #9 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #8 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #8 errors of type = ERROR q -404 Head positioning failed to converge. Found #8 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #7 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #7 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. Found #7 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #5 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #5 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #5 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #5 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #4 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #4 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #4 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. Found #3 errors of type = ERROR qd -301 Synch block CRC checksum test FAILED. Found #3 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #2 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #2 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #2 errors of type = ERROR ch -329 Formatter time does not agree with Field System time. Found #2 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 5 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 23 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 13 sync errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. Found #1 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. Found #1 errors of type = ERROR ch -337 Reproduce bandwidth does not check with request Found #1 errors of type = ERROR ch -338 Reproduce equalizer does not check with request Found #1 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #1 errors of type = ERROR ch -201 hd communication trouble Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #1 errors of type = ERROR qg -304 Track 3 sync errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #1 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 11 sync errors exceed threshold. Found #1 errors of type = ERROR ch -327 Formatter's run set switch is in SET position Found #1 errors of type = ERROR qg -304 Track 21 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 15 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 17 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 25 sync errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #1 errors of type = ERROR qg -304 Track 19 sync errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #1 errors of type = ERROR ch -332 Tape drive is not in remote Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found these BBCs: vc06 vc11 NBBC: 2 Found these RX parameters: 00(front) 01(rear) 02(lo) RX1 min= 10.80 max= 21.30 RX2 min= 25.09 max= 35.71 RX3 min= 35.71 max= 42.30 Plotting 2 Tsys channels: 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 2 in match_chan ft1= ca083ho.log.tsy1.ntup nt1= 11 st1= v6 tt= 1 set scale tsys1 [2] min max 45.1 99999 set scale tsys2 [2] min max 55.6 6315.0 set scale tsys3 [2] min max Tsys scale ymin 0.1 ymax 58.4 in match_chan ft1= ca083ho.log.tsy2.ntup nt1= 8 st1= v11 tt= 2 set scale tsys1 [2] min max 45.1 99999 set scale tsys2 [2] min max 55.6 6315.0 set scale tsys3 [2] min max Tsys scale ymin 55.6 ymax 100