Starting generation of Calibration File FS version = 0009.0004.0002 time_zero = 7059600 Rack type is MK3/4 Found #120 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #103 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #60 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #42 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #30 errors of type = ERROR ch -309 vb alarm is on Found #30 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #16 errors of type = ERROR ch -307 vb unlock indicator is on Found #14 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #13 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #11 errors of type = ERROR ch -303 v6 bandwidth does not check with requested value Found #8 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #8 errors of type = ERROR ch -4 Device vf timed-out on response from MATCN Found #6 errors of type = ERROR ch -309 v3 alarm is on Found #6 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #6 errors of type = ERROR ch -309 v6 alarm is on Found #4 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #4 errors of type = ERROR ch -301 vb module is not in remote Found #3 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 31 parity errors exceed threshold. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR ch -233 rc tape drive should be moving and it isn't Found #1 errors of type = ERROR qn -201 Error in request. Must be ALL EVEN ODD IF FM TP V1...V15 HD RX. Found #1 errors of type = ERROR qg -303 Track 29 parity errors exceed threshold. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= ca082ma.log.tsy1.ntup nt1= 7 st1= v2 tt= 1 set scale tsys1 [2] min max 16.5 1501.2 set scale tsys2 [2] min max 33.0 99999 set scale tsys3 [2] min max Tsys scale ymin 45.2 ymax 65.7 in match_chan ft1= ca082ma.log.tsy1.ntup nt1= 11 st1= v6 tt= 1 set scale tsys1 [2] min max 16.5 1501.2 set scale tsys2 [2] min max 33.0 99999 set scale tsys3 [2] min max Tsys scale ymin 49.7 ymax 85.9 in match_chan ft1= ca082ma.log.tsy2.ntup nt1= 8 st1= v11 tt= 2 set scale tsys1 [2] min max 16.5 1501.2 set scale tsys2 [2] min max 33.0 99999 set scale tsys3 [2] min max Tsys scale ymin 33.0 ymax 100