Starting generation of Calibration File FS version = 0009.0004.0002 time_zero = 2221200 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Found #189 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #97 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #76 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #46 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #46 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #16 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #16 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #16 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #12 errors of type = ERROR st -42 Found #8 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #6 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #5 errors of type = ERROR ch -303 v8 bandwidth does not check with requested value Found #5 errors of type = ERROR ch -306 v8 LSB attenuator does not check with requested setting Found #5 errors of type = ERROR ch -304 v7 TPI selection does not check with requested setting Found #5 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #5 errors of type = ERROR ch -302 v7 frequency does not check with requested value Found #5 errors of type = ERROR ch -306 v7 LSB attenuator does not check with requested setting Found #5 errors of type = ERROR ch -305 v7 USB attenuator does not check with requested setting Found #5 errors of type = ERROR ch -302 v8 frequency does not check with requested value Found #5 errors of type = ERROR pt -102 [PTRAK] - LU has timed out. Continue tracking. Found #5 errors of type = ERROR ch -303 v7 bandwidth does not check with requested value Found #5 errors of type = ERROR ch -304 v8 TPI selection does not check with requested setting Found #4 errors of type = ERROR st -105 [ANCOM] - Too many errors from LU . Found #4 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #2 errors of type = ERROR ch -302 v5 frequency does not check with requested value Found #2 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #2 errors of type = ERROR ch -306 v5 LSB attenuator does not check with requested setting Found #2 errors of type = ERROR rc -201 Parameter must be reboot load unload bot eot release feet or zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #2 errors of type = ERROR ch -309 v5 alarm is on Found #2 errors of type = ERROR ch -303 v5 bandwidth does not check with requested value Found #2 errors of type = ERROR ch -307 v5 unlock indicator is on Found #2 errors of type = ERROR ch -304 v5 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -309 v6 alarm is on Found #1 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #1 errors of type = ERROR ch -309 v8 alarm is on Found #1 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 16. Found #1 errors of type = ERROR qg -303 Track 6 parity errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #1 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR pt -103 [PTRAK] - No response from LU . PTRAK aborted. Found #1 errors of type = ERROR ch -309 vb alarm is on Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= ca080ma.log.tsy1.ntup nt1= 7 st1= v2 tt= 1 set scale tsys1 [2] min max 21.9 95.7 set scale tsys2 [2] min max 8.8 5773.1 set scale tsys3 [2] min max Tsys scale ymin 44.4 ymax 90.7 in match_chan ft1= ca080ma.log.tsy1.ntup nt1= 11 st1= v6 tt= 1 set scale tsys1 [2] min max 21.9 95.7 set scale tsys2 [2] min max 8.8 5773.1 set scale tsys3 [2] min max Tsys scale ymin 20.2 ymax 100 in match_chan ft1= ca080ma.log.tsy2.ntup nt1= 8 st1= v11 tt= 2 set scale tsys1 [2] min max 21.9 95.7 set scale tsys2 [2] min max 8.8 5773.1 set scale tsys3 [2] min max Tsys scale ymin 8.8 ymax 100