Starting generation of Calibration File FS version = 0009.0004.0001 time_zero = 1011600 Rack type is MK3/4 Rack type is MK3/4 Found #39 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #4 errors of type = ERROR ib -4 GPIB Device time-out on response gt Found #3 errors of type = ERROR ma -4 Device de timed-out on response. Found #2 errors of type = ERROR qg -304 Track 26 sync errors exceed threshold. Found #2 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #2 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #1 errors of type = ERROR ma -701 MK4 DE unknown command Found #1 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 8 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #1 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these RX parameters: 00(FRONT) 01(REAR) 02(LO) RX1 min= 4.335 max= 10.80 RX2 min= 12.39 max= 18.74 RX3 min= 11.17 max= 17.64 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= ca079wf.log.tsy1.ntup nt1= 7 st1= v2 tt= 1 set scale tsys1 [2] min max 45.7 15271.3 set scale tsys2 [2] min max 48.8 4531.5 set scale tsys3 [2] min max Tsys scale ymin 47.1 ymax 100 in match_chan ft1= ca079wf.log.tsy1.ntup nt1= 11 st1= v6 tt= 1 set scale tsys1 [2] min max 45.7 15271.3 set scale tsys2 [2] min max 48.8 4531.5 set scale tsys3 [2] min max Tsys scale ymin 52.3 ymax 88.3 in match_chan ft1= ca079wf.log.tsy2.ntup nt1= 8 st1= v11 tt= 2 set scale tsys1 [2] min max 45.7 15271.3 set scale tsys2 [2] min max 48.8 4531.5 set scale tsys3 [2] min max Tsys scale ymin 48.8 ymax 100