Starting generation of Calibration File FS version = 0009.0004.0002 time_zero = 1011600 Rack type is MK3/4 Found #167 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #126 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #97 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #50 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #41 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #15 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #14 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #9 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #7 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #7 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #4 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #2 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 26 parity errors exceed threshold. Found #1 errors of type = ERROR ch -309 v3 alarm is on Found #1 errors of type = ERROR qg -303 Track 30 parity errors exceed threshold. Found #1 errors of type = ERROR ch -309 vb alarm is on Found #1 errors of type = ERROR ch -309 v6 alarm is on Found #1 errors of type = ERROR qg -303 Track 16 parity errors exceed threshold. Found #1 errors of type = ERROR pt -102 [PTRAK] - LU has timed out. Continue tracking. Found #1 errors of type = ERROR qg -303 Track 24 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= ca079ma.log.tsy1.ntup nt1= 7 st1= v2 tt= 1 set scale tsys1 [2] min max 27.3 102.1 set scale tsys2 [2] min max 18.8 24490.4 set scale tsys3 [2] min max Tsys scale ymin 53.5 ymax 88.7 in match_chan ft1= ca079ma.log.tsy1.ntup nt1= 11 st1= v6 tt= 1 set scale tsys1 [2] min max 27.3 102.1 set scale tsys2 [2] min max 18.8 24490.4 set scale tsys3 [2] min max Tsys scale ymin 23.1 ymax 100 in match_chan ft1= ca079ma.log.tsy2.ntup nt1= 8 st1= v11 tt= 2 set scale tsys1 [2] min max 27.3 102.1 set scale tsys2 [2] min max 18.8 24490.4 set scale tsys3 [2] min max Tsys scale ymin 18.8 ymax 100