Starting generation of Calibration File FS version = 0009.0004.0013 time_zero = 25290000 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Found #94 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #81 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #34 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #15 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #6 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #3 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #3 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #2 errors of type = ERROR qg -303 Track 32 parity errors exceed threshold. Found #2 errors of type = ERROR qg -303 Track 33 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 33. Found #1 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 26. Found #1 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 8. Found #1 errors of type = ERROR ch -233 rc tape drive should be moving and it isn't Found #1 errors of type = ERROR qg -303 Track 8 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 14 parity errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #1 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #1 errors of type = ERROR st -115 [ANTCN] - WARNING: X S paths are not in line. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 32. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= c3004ma.log.tsy1.ntup nt1= 7 st1= v2 tt= 1 set scale tsys1 [2] min max 50.9 97.8 set scale tsys2 [2] min max 46.9 110715.0 set scale tsys3 [2] min max Tsys scale ymin 50.8 ymax 97.8 in match_chan ft1= c3004ma.log.tsy1.ntup nt1= 11 st1= v6 tt= 1 set scale tsys1 [2] min max 50.9 97.8 set scale tsys2 [2] min max 46.9 110715.0 set scale tsys3 [2] min max Tsys scale ymin 39.2 ymax 100 in match_chan ft1= c3004ma.log.tsy2.ntup nt1= 8 st1= v11 tt= 2 set scale tsys1 [2] min max 50.9 97.8 set scale tsys2 [2] min max 46.9 110715.0 set scale tsys3 [2] min max Tsys scale ymin 46.9 ymax 100