Starting generation of Calibration File FS version = 0009.0004.0006 time_zero = 26326800 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Rack type is MK3/4 Found #250 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #58 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #31 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #29 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #26 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 70K. Found #25 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #23 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #21 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #18 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #16 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #15 errors of type = ERROR ch -332 Tape drive is not in remote Found #14 errors of type = ERROR qg -304 Track 25 sync errors exceed threshold. Found #14 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #11 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #7 errors of type = ERROR q -404 Head positioning failed to converge. Found #7 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #7 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #6 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #6 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #6 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. Found #6 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #6 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #6 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. Found #6 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #6 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #6 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #5 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #5 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #5 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #5 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. Found #5 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #5 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #5 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #5 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #5 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #5 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #5 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #5 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #4 errors of type = ERROR q< -301 Vacuum is not ready. Found #4 errors of type = ERROR ch -341 Reproduce track B does not check with request Found #4 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #4 errors of type = ERROR ch -340 Reproduce track A does not check with request Found #3 errors of type = ERROR qg -304 Track 27 sync errors exceed threshold. Found #3 errors of type = ERROR qd -301 Synch block CRC checksum test FAILED. Found #3 errors of type = ERROR qg -315 Bandwidth must be set with repro command first. Found #2 errors of type = ERROR qg -304 Track 5 sync errors exceed threshold. Found #2 errors of type = ERROR ch -333 Tape should be stopped and it's moving Found #2 errors of type = ERROR qg -306 No tracks selected was command set-up Found #2 errors of type = ERROR ch -346 Record enable is in the wrong state. Found #1 errors of type = ERROR qn -201 Error in request. Must be ALL EVEN ODD IF FM TP V1...V15 HD RX. Found #1 errors of type = ERROR ch -338 Reproduce equalizer does not check with request Found #1 errors of type = ERROR bo -211 Can't open a new schedule when an experiment procedure is executing Found #1 errors of type = ERROR ch -337 Reproduce bandwidth does not check with request Found these BBCs: vc06 vc11 vc06 NBBC: 3 Found these RX parameters: 00(front) 01(rear) 02(lo) RX1 min= 11.05 max= 32.05 RX2 min= 24.48 max= 44.26 RX3 min= 34.49 max= 51.58 Plotting 3 Tsys channels: 06 11 06 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= c1005ho.log.tsy1.ntup nt1= 11 st1= v6 tt= 1 set scale tsys1 [2] min max 153.4 334.9 set scale tsys2 [2] min max 91.9 148.5 set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100 in match_chan ft1= c1005ho.log.tsy2.ntup nt1= 8 st1= v11 tt= 2 set scale tsys1 [2] min max 153.4 334.9 set scale tsys2 [2] min max 91.9 148.5 set scale tsys3 [2] min max Tsys scale ymin 91.9 ymax 100 in match_chan ft1= c1005ho.log.tsy1.ntup nt1= 11 st1= v6 tt= 1 set scale tsys1 [2] min max 153.4 334.9 set scale tsys2 [2] min max 91.9 148.5 set scale tsys3 [2] min max Tsys scale ymin 0 ymax 100