Starting generation of Calibration File FS version = 0009.0004.0006 time_zero = 22694400 Rack type is MK3/4 Found #342 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 70K. Found #35 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #25 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #22 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #16 errors of type = ERROR ch -338 Reproduce equalizer does not check with request Found #16 errors of type = ERROR ch -337 Reproduce bandwidth does not check with request Found #13 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #10 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #7 errors of type = ERROR ch -309 v3 alarm is on Found #5 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #4 errors of type = ERROR q -404 Head positioning failed to converge. Found #3 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #1 errors of type = ERROR ch -332 Tape drive is not in remote Found #1 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #1 errors of type = ERROR q< -301 Vacuum is not ready. Found #1 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #1 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #1 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found these BBCs: vc06 vc11 NBBC: 2 Found these RX parameters: 00(front) 01(rear) 02(lo) RX1 min= 11.78 max= 22.65 RX2 min= 25.58 max= 35.59 RX3 min= 35.83 max= 42.30 Plotting 2 Tsys channels: 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 2 in match_chan ft1= c1003ho.log.tsy1.ntup nt1= 11 st1= v6 tt= 1 set scale tsys1 [2] min max 50.8 319.2 set scale tsys2 [2] min max 64.6 138.5 set scale tsys3 [2] min max Tsys scale ymin 41.3 ymax 100 in match_chan ft1= c1003ho.log.tsy2.ntup nt1= 8 st1= v11 tt= 2 set scale tsys1 [2] min max 50.8 319.2 set scale tsys2 [2] min max 64.6 138.5 set scale tsys3 [2] min max Tsys scale ymin 64.6 ymax 100