Starting generation of Calibration File FS version = 0009.0004.0013 time_zero = 16650000 Rack type is MK3/4 Found #99 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #98 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #68 errors of type = ERROR qk -211 Tsys value for device vb overflowed or were less than zero. Found #56 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #48 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #14 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #3 errors of type = ERROR ch -309 vb alarm is on Found #2 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #2 errors of type = ERROR qk -211 Tsys value for device vc overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 6 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 4 sync errors exceed threshold. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 12. Found #1 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #1 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #1 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #1 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 4 parity errors exceed threshold. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= c1001ma.log.tsy1.ntup nt1= 7 st1= v2 tt= 1 set scale tsys1 [2] min max 37.7 92.6 set scale tsys2 [2] min max 28.6 99999 set scale tsys3 [2] min max Tsys scale ymin 50.8 ymax 91.9 in match_chan ft1= c1001ma.log.tsy1.ntup nt1= 11 st1= v6 tt= 1 set scale tsys1 [2] min max 37.7 92.6 set scale tsys2 [2] min max 28.6 99999 set scale tsys3 [2] min max Tsys scale ymin 54.4 ymax 100 in match_chan ft1= c1001ma.log.tsy2.ntup nt1= 8 st1= v11 tt= 2 set scale tsys1 [2] min max 37.7 92.6 set scale tsys2 [2] min max 28.6 99999 set scale tsys3 [2] min max Tsys scale ymin 28.6 ymax 100